Part of the Oxford Instruments Group
Expand
Electronics X-ray Inspection

Electronics X-ray Inspection

No description.


Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Max Filament Current (A) Spot Size (µm)**
X-ray Tube, Neptune Pkg, Mo, HP 93211* 8250 Mo 10 - 50 2.0 100 2.4 175 Max. Add to quote list
X-ray Tube, Neptune Pkg, W, HP 93212* 8250 W 10 - 50 2.0 100 2.4 175 Max. Add to quote list
X-ray Tube, Neptune Pkg, Rh, HP 93221* 8250 Rh 10 - 50 2.0 100 2.4 375 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Max Filament Current (A) Spot Size (µm)**
X-ray Tube, Jupiter Pkg, W, HP 93000* 8166 W 10 - 50 1.0 50 1.7 165 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, HP 93001 8166 Mo 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Ag, STD 93025 8166 Ag 4 - 50 1.0 50 1.3 1000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Au, STD 93035 8166 Au 10 - 50 1.0 25 1.3 1000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, STD, O-ring 93046 8208 Mo 4 - 50 1.0 50 1.3 1000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Cu, HP 93048 8166 Cu 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Rh, HP 93057 8166 Rh 10 - 50 1.0 50 1.7 180 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Rh, HP, VacFlange 93059 8203 Rh 10 - 50 1.0 50 1.7 180 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, HP 93069* 8166 W 10 - 50 1.0 50 1.7 70 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Cr, HP 93070 8166 Cr 10 - 50 1.0 50 1.7 200 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, HP, VacFlange 93071 8203 W 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Ti, STD 93072 8166 Ti 4 - 50 1.0 50 1.3 1000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Pd, HP 93073 8166 Pd 10 - 50 1.0 50 1.7 200 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Cu, HP, VacFlange 93078* 8203 Cu 10 - 50 1.0 50 1.7 175 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, HP, VacFlange 93079* 8203 Mo 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, VHP 93089* 8166 W 10 - 50 1.0 50 1.7 50 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, VHP 93095* 8166 Mo 20 - 50 1.0 50 1.7 55 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Fe, STD 2mA 50W 93512* 8166 Fe 4 - 50 2.0 50 1.4 1000 Typ. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Max Filament Current (A) Spot Size (µm)**
X-ray Tube, Apogee Pkg, Cu, VHP 93500* 8243 Cu 10 - 50 1.0 50 1.7 35 Nom. Add to quote list
X-ray Tube, Apogee Pkg, W, VHP 93501* 8243 W 10 - 50 1.0 50 1.7 35 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Mo, VHP 93502* 8243 Mo 10 - 50 1.0 50 1.7 35 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Rh, VHP 93504* 8243 Rh 10 - 50 1.0 20 1.7 35 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Cu, VHP 93508* 8243 Cu 10 - 50 1.0 50 1.7 35 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Cu, VHP 93510* 8243 Cu 10 - 50 1.0 50 1.7 35 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Mo, VHP 93511* 8243 Mo 10 - 50 1.0 50 1.7 35 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Mo, VHP, 55kV 9300005 8243 Mo 10 - 55 1.0 50 1.7 35 Nom. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Max Filament Current (A) Spot Size (µm)**
X-ray Tube, 1000 Glass, W, HP, BiPolar 90501 8218 W 40 - 80 0.7 56 1.7 100 Max. Add to quote list
X-ray Tube, 1000 Glass, W, HP 90502 8218 W 40 - 65 0.5 32.5 1.7 90 Max. Add to quote list
X-ray Tube, 1000 Glass, W, VHP, BiPolar 90507 8218 W 40 - 80 0.5 40 1.7 33 Nom. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Max Filament Current (A) Spot Size (µm)**
X-ray Tube, 1500 Glass, Rh, HP, Long Ext 90011 8194 Rh 10 - 50 1.0 50 1.7 150 Max. Add to quote list
X-ray Tube, 1500 Glass, Cr, HP 90034 8188 Cr 10 - 50 1.0 50 1.7 200 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, 5mA, IND 90046 8162 W 4 - 50 5.0 250 2.4 500 Typ. Add to quote list
X-ray Tube, 1500 Glass, Mo, HP 90068 8188 Mo 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, 1500 Glass, Cu, HP 90069 8188 Cu 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, 1500 Glass, Rh, HP 90077 8188 Rh 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, HP 90083 8188 W 10 - 50 1.0 50 1.7 150 Typ. Add to quote list
X-ray Tube, 1500 Glass, Fe, 5mA, IND 90098 8162 Fe 4 - 50 5.0 200 2.4 500 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, HP 90099 8189 W 10 - 50 1.0 50 1.7 70 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Max Filament Current (A) Spot Size (µm)**
X-ray Tube, 1550 Glass, Cu, VHP 90200 8242 Cu 10 - 50 1.0 50 1.7 50 Max. Add to quote list
X-ray Tube, 1550 Glass, W, VHP 90201 8242 W 10 - 50 1.0 50 1.7 50 Max. Add to quote list
X-ray Tube, 1550 Glass, Mo, VHP 90202 8242 Mo 10 - 50 1.0 50 1.7 50 Max. Add to quote list
X-ray Tube, 1550 Glass, Rh, VHP 90204 8242 Rh 10 - 50 1.0 50 1.7 50 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Cable Orientation HV Cable Length DIM "A" Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Spot Size (µm)**
X-ray Microfocus, Pinnacles 50kV, W, 1m, 90 Deg 9400001 8400001 Side Exit 39 in (1m) W 10 - 50 1.0 12 10 Nom. Add to quote list
X-ray Microfocus, Pinnacles 50kV, W, 1m, 180 Deg 9400003 8400002 End Exit 39 in (1m) W 10 - 50 1.0 12 10 Nom. Add to quote list
X-ray Microfocus, Pinnacles 50kV, W, 2m, 180 Deg 9400014 8400002 End Exit 79 in (2m) W 10 - 50 1.0 12 10 Nom. Add to quote list
X-ray Microfocus, Pinnacles 50kV, W, 3m, 180 Deg 9400015 8400002 End Exit 118 in (3m) W 10 - 50 1.0 12 10 Nom. Add to quote list
x射线微焦点,尖塔50 kv, W, 2 m, 90Deg 9400017 8400001 Side Exit 79 in (2m) W 10 - 50 1.0 12 10 Nom. Add to quote list
X-ray Microfocus, Pinnacles 50kV, W, 3m, 90 Deg 9400018 8400001 Side Exit 118 in (3m) W 10 - 50 1.0 12 10 Nom. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Power Density Spot Size (µm)**
X-ray Microfocus, UltraBright, 60kV, Cu 96000* 8236 Cu 20 - 60 2.0 60 1.5W/µm 20 Max. Add to quote list
X-ray Microfocus, UltraBright, 60kV, Mo 96002* 8236 Mo 20 - 60 2.0 60 1.5W/µm 20 Max. Add to quote list
X-ray Microfocus, UltraBright, 90kV, W 96004* 8236 W 20 - 90 2.0 80 2.5W/µm 20 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part Number Outline Drawing Target Operating Range (kV) Max Anode Current (mA) Max Anode Power (W) Power Density Spot Size (µm)**
X-ray Microfocus, Nova 600, 90kV, W 96013* 8240 W 20 - 90 2.0 80 2.5W/µm 20 Max. Add to quote list
X-ray Microfocus, Nova 600, 60kV, Mo 96016* 8240 Mo 20 - 60 2.0 60 1.5W/µm 20 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List